Ошибки mps6 / 6dct450 powershift
| DTC | Description | Action |
| P0603 | EEPROM fault | INSTALL a new TCM |
| P060A | Internal Control Module, Monitoring Processor Performance | INSTALL a new TCM |
| P073E | gear R engagement blocking (after internal handling) | INSTALL a new transmission |
| P073F | gear 1 engagement blocking (after internal handling) | INSTALL a new transmission |
| P074A | gear 2 engagement blocking (after internal handling) | INSTALL a new transmission |
| P074B | gear 3 engagement blocking (after internal handling) | INSTALL a new transmission |
| P074C | gear 4 engagement blocking (after internal handling) | INSTALL a new transmission |
| P074D | gear 5 engagement blocking (after internal handling) | INSTALL a new transmission |
| P0791 | In shaft 1 speed sensor defect, current out of range | INSTALL a new TCM |
| P0792 | Input shaft speed 1 defect | INSTALL a new TCM |
| P0847 | Clutch 2 Pressure sensor voltage below normal operation voltage | INSTALL a new TCM |
| P0711 | Hydraulic, hybrid temperature sensor plausibility failure | INSTALL a new TCM |
| P0715 | Damper speed sensor defect | INSTALL a new TCM |
| P0766 | CSMS1 / CSM1 sticks low / low oil level | CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
| P0771 | CSMS2 / CSM2 sticks low / low oil level | CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
| P0796 | Clutch 1 Plausibility Failure pressure too low | CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
| P2714 | Clutch 2 Plausibility Failure pressure too low | CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
| P2715 | Clutch 2 Plausibility Failure pressure too high | CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
| P0841 | Clutch 1 Torque Plausibility Failure | INSTALL a new Clutch, if symptoms persist INSTALL a new TCM |
| P0846 | Clutch 2 Torque Plausibility Failure | INSTALL a new Clutch, if symptoms persist INSTALL a new TCM |
| P2746 | transmission path 2 speed plausibility error | INSTALL a new TCM |
| P1905 | EOL Mode active | INSTALL a new TCM |
| P0949 | Teaching not completed | Check for the latest TCM software level, Run Teach in routine using the Ford diagnostic equipment. |
| P171A | shift fork 1 requested but movement on shift fork 2 | INSTALL a new TCM If symptoms persist INSTALL a new transmission |
| P171C | shift fork 2 requested but movement on shift fork 1 | INSTALL a new TCM If symptoms persist INSTALL a new transmission |
| P171D | shift fork 2 requested but movement on shift fork 4 | INSTALL a new TCM If symptoms persist INSTALL a new transmission |
| P171F | shift fork 3 requested but movement on shift fork 4 | INSTALL a new TCM If symptoms persist INSTALL |
| P172C | shift fork ½ movement in opposite direction (to left cylinder) | INSTALL a new TCM If symptoms persist INSTALL a new transmission |
| P0581 | SHSS1 current driver error: Short to Battery | INSTALL a new TCM |
| P0798 | CSPS1 valve current driver error: overcurrent | INSTALL a new TCM |
| P2716/9 | CSPS2 valve current driver error: overcurrent | INSTALL a new TCM |
| P2720 | CSPS2 valve current error: Short to Ground | INSTALL a new TCM |
| P0964 | CCFS current driver error Open load | INSTALL a new TCM |
| P0979 | SHCMS current driver error: Short to Ground | INSTALL a new TCM |
| P0753 | SHSS1 current driver error: Open load | INSTALL a new TCM |
| P0778 | CCFS current driver error: overcurrent | INSTALL a new TCM |
| P0657 | Common high side driver 1 not functional | INSTALL a new TCM |
| P092C | Shift lock output short to Ground / Open Load | CHECK wiring for continuity, if symptoms persist INSTALL a new TCM |
| P081B | Start lock output error: Short to Battery | CHECK wiring for short, if symptoms persist INSTALL a new TCM |
| P283B | shift fork position 3 position range error (in counts) | INSTALL a new TCM |
| P283D | shift fork position sensor 3 low output voltage failure | INSTALL a new TCM |
| P2840 | shift fork position 4 position range error (in counts) | INSTALL a new TCM |
| P2842 | shift fork position sensor 4 low output voltage failure | INSTALL a new TCM |
| P2846 | shift fork position sensor 2 neutral plausibility error | INSTALL a new TCM |
| P2849 | shift fork 1 blocked completely and no unexpected movement on other shift fork | INSTALL a new transmission |
| P284A | shift fork 2 blocked completely and no unexpected movement on other shift fork | INSTALL a new transmission |
| P284B | shift fork 3 blocked completely and no unexpected movement on other shift fork | INSTALL a new transmission |
| P284C | shift fork 4 blocked completely and no unexpected movement on other shift fork | INSTALL a new transmission |
| P284D | shift fork 1 movement but not requested | INSTALL a new TCM |
| P284F | shift fork 3 movement but not requested | INSTALL a new TCM |
| P2850 | shift fork 4 movement but not requested | INSTALL a new TCM |
| P0733 | shift fork 2 jump out from forward towards the engine (left side) | INSTALL a new TCM If symptoms persist INSTALL |
| P0734 | shift fork 3 jump out from rearward towards the engine (right side) | INSTALL a new TCM If symptoms persist INSTALL a new transmission |